Customization: | Available |
---|---|
Certification: | CE, FDA, EEC, ISO13485 |
Model: | Bio-1100 |
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
* Rigorous implementation of Goldman international standard.
* Halogen projection system:Stimulation light source is from wide band visible spectrum, fully meet colored cone cell stimulation.
* Accurate and elaborate database of normal population of all age groups, recognition of more subtle early visual field defects.
* GHT glaucoma semi vision analysis, make glaucoma diagnosis easier.
* GPA glaucoma progression analysis upgrade, slight glaucoma development is obvious.
* Standard SWAP blue-yellow visual field examination, sensitive to earlier visual field defects * Scientific and intelligent interactive inspection strategy, 30° range visual field inspection only takes 3 minutes.
* Simple one-stop modular software design, equipment operation learning only 2 minutes
*.Zeiss humphrey 860 same function
Specification |
||
Testing scope |
90° |
|
Testing distance |
30CM |
|
Background light |
white31.5asb,yellow315asb |
|
Visual target |
0.08asb---10000asb(0-51DB) |
|
Target size |
Goldmann I, II ,III,IV,V |
|
Visual target stimulation time |
200ms |
|
Visual target interval time |
Standard and custom |
|
Threshold policy |
Macula,10-2,24-2,30-2,60-4,nasal side |
|
Upper threshold policy |
C-40,C-64,C-76,FF-81,FF-120,FF-135... |
|
Special detection strategy |
Esterman monocular,Esterman binocular,upper36°screening,blind point testing |
|
Yellow-blue testing |
Standard 440nm blue visual target + 315asb OG530yellow background brightness |
|
Visual target |
Red ,blue |
|
Dynamic policy |
Standard dynamic,blind dynamic,dark spot dynamic ,straight line dynamic |
|
Custom policy |
Static custom dynamic custom |
|
Pupil size measurement |
Auto |
|
Fixation monitoring |
Physiological blind spot monitoring,eye position monitoring,eye position moving alarm,eye tracking curve |
|
Environment light testing |
Auto |
|
Analysis software |
reliability analysis , single report, triple report, GHT glaucoma semi vision report, GPA glaucoma developing analysis, VFI analysis, Blue-yellow analysis |
|
System |
Win7 above |
|
Others |
||
Size |
412mm(length)* 497mm(width)* 513mm(height) |
|
Wight |
17kg |
|
Power |
100-240V HZ:50-60Hz |
Comparison of proection perimeter
MODEL | BIO-1100 (appearance same as zeiss) | zeiss 830 | zeiss 840 | zeiss 850 | zeiss 860 |
background light | 31.5ASB | 31.5ASB | |||
light source | Halogen | Halogen | |||
fixation monitor | |||||
Heijl-krakau blind point monitor | √ | √ | √ | √ | √ |
video monitor | √ | √ | √ | √ | √ |
stare monitor | √ | √ | √ | √ | |
operation interface | |||||
screen | Touch LCD screen | ||||
keyboard | √ | √ | √ | √ | √ |
visual target | |||||
white-white | √ | √ | √ | √ | √ |
red-white blue-white | √ | √ | √ | √ | |
blue-yellow(SWAP) | √ | √ | √ | ||
testing feature | |||||
visual size | Goldman I-V | ||||
macular threshold testing | √ | √ | √ | √ | |
pupil size test | √ | √ | √ | √ | |
liquid trail lens | √ | ||||
RelEYE monitor | √ | √ | √ | ||
test program | |||||
customization | √ | √ | √ | √ | √ |
software | |||||
single filed analysis (SFA) | √ | √ | √ | √ | √ |
glaucoma half test(GHT) | √ | √ | √ | √ | √ |
visual filed index(VFI) | √ | √ | √ | √ | √ |
glaucoma progress analysis(GPA) | √ | √ | √ | √ | √ |
Visual field sequence view | √ | √ | √ | √ | √ |